kernel_samsung_a53x/drivers/pwm
Erik Schumacher ae14643f35 pwm: imx-tpm: Use correct MODULO value for EPWM mode
commit cc6a931d1f3b412263d515fd93b21fc0ca5147fe upstream.

The modulo register defines the period of the edge-aligned PWM mode
(which is the only mode implemented). The reference manual states:
"The EPWM period is determined by (MOD + 0001h) ..." So the value that
is written to the MOD register must therefore be one less than the
calculated period length. Return -EINVAL if the calculated length is
already zero.
A correct MODULO value is particularly relevant if the PWM has to output
a high frequency due to a low period value.

Fixes: 738a1cfec2ed ("pwm: Add i.MX TPM PWM driver support")
Cc: stable@vger.kernel.org
Signed-off-by: Erik Schumacher <erik.schumacher@iris-sensing.com>
Link: https://lore.kernel.org/r/1a3890966d68b9f800d457cbf095746627495e18.camel@iris-sensing.com
Signed-off-by: Uwe Kleine-König <ukleinek@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2024-11-30 02:33:24 +01:00
..
core.c
Kconfig
Makefile
pwm-ab8500.c
pwm-atmel-hlcdc.c
pwm-atmel-tcb.c
pwm-atmel.c
pwm-bcm-iproc.c
pwm-bcm-kona.c
pwm-bcm2835.c
pwm-berlin.c
pwm-brcmstb.c
pwm-clps711x.c
pwm-crc.c
pwm-cros-ec.c
pwm-ep93xx.c
pwm-fsl-ftm.c
pwm-hibvt.c
pwm-img.c
pwm-imx-tpm.c pwm: imx-tpm: Use correct MODULO value for EPWM mode 2024-11-30 02:33:24 +01:00
pwm-imx1.c
pwm-imx27.c
pwm-iqs620a.c
pwm-jz4740.c
pwm-lp3943.c
pwm-lpc18xx-sct.c
pwm-lpc32xx.c
pwm-lpss-pci.c
pwm-lpss-platform.c
pwm-lpss.c
pwm-lpss.h
pwm-mediatek.c
pwm-meson.c
pwm-mtk-disp.c
pwm-mxs.c
pwm-omap-dmtimer.c
pwm-pca9685.c
pwm-pxa.c
pwm-rcar.c
pwm-renesas-tpu.c
pwm-rockchip.c
pwm-samsung.c driver: pwm: Implement .apply() callback 2024-11-30 02:19:17 +01:00
pwm-sifive.c
pwm-sl28cpld.c
pwm-spear.c
pwm-sprd.c
pwm-sti.c
pwm-stm32-lp.c
pwm-stm32.c
pwm-stmpe.c
pwm-sun4i.c
pwm-tegra.c
pwm-tiecap.c
pwm-tiehrpwm.c
pwm-twl-led.c
pwm-twl.c
pwm-vt8500.c
pwm-zx.c
sysfs.c