* s2mf301_fuelgauge.h - Header of S2MF301 Fuel Gauge
|
|
*
|
|
* Copyright (C) 2018 Samsung Electronics, Inc.
|
|
*
|
|
* This program is free software; you can redistribute it and/or
|
|
* modify it under the terms of the GNU General Public License
|
|
* as published by the Free Software Foundation; either version 2
|
|
* of the License, or (at your option) any later version.
|
|
*
|
|
* This program is distributed in the hope that it will be useful,
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
* GNU General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License
|
|
* along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
*
|
|
*/
|
|
|
|
#ifndef __S2MF301_FUELGAUGE_H
|
|
#define __S2MF301_FUELGAUGE_H __FILE__
|
|
|
|
#if IS_ENABLED(ANDROID_ALARM_ACTIVATED)
|
|
#include <linux/android_alarm.h>
|
|
#endif
|
|
#include <linux/power/s2m_chg_manager.h>
|
|
#include <linux/mfd/samsung/s2mf301.h>
|
|
|
|
/* Slave address should be shifted to the right 1bit.
|
|
* R/W bit should NOT be included.
|
|
*/
|
|
|
|
#define USE_EXTERNAL_TEMP 0
|
|
|
|
#define TEMP_COMPEN 1
|
|
#define BATCAP_LEARN 1
|
|
|
|
#define S2MF301_REG_STATUS 0x00
|
|
#define S2MF301_REG_FG_INT 0x02
|
|
#define S2MF301_REG_FG_IMTM 0x03
|
|
#define S2MF301_REG_RVBAT 0x04
|
|
#define S2MF301_REG_RCUR_CC 0x06
|
|
#define S2MF301_REG_RSOC 0x08
|
|
#define S2MF301_REG_MONOUT 0x0A
|
|
#define S2MF301_REG_MONOUT_SEL 0x0C
|
|
#define S2MF301_REG_RBATCAP 0x0E
|
|
#define S2MF301_REG_BATCAP 0x10
|
|
#define S2MF301_REG_CAPCC 0x3E
|
|
#define S2MF301_REG_RSOC_R 0x2A
|
|
|
|
#define S2MF301_REG_RZADJ 0x12
|
|
#define S2MF301_REG_RBATZ0 0x16
|
|
#define S2MF301_REG_RBATZ1 0x18
|
|
#define S2MF301_REG_IRQ_LVL 0x1A
|
|
#define S2MF301_REG_START 0x1E
|
|
|
|
#define BATT_TEMP_CONSTANT 250
|
|
|
|
/* Use reserved register region 0x48[3:0]
|
|
* For battery parameter version check
|
|
*/
|
|
#define S2MF301_REG_FG_ID 0x48
|
|
|
|
#define S2MF301_REG_VM 0x67
|
|
|
|
enum {
|
|
CURRENT_MODE = 0,
|
|
LOW_SOC_VOLTAGE_MODE, // not used
|
|
HIGH_SOC_VOLTAGE_MODE,
|
|
END_MODE,
|
|
};
|
|
|
|
static char* mode_to_str[] = {
|
|
"CC_MODE",
|
|
"VOLTAGE_MODE", // not used
|
|
"VOLTAGE_MODE",
|
|
"END",
|
|
};
|
|
|
|
struct fg_info {
|
|
/* battery info */
|
|
int soc;
|
|
int battery_profile_index;
|
|
|
|
int battery_table3[88];
|
|
int battery_table4[22];
|
|
int soc_arr_val[22];
|
|
int ocv_arr_val[22];
|
|
int batcap[4];
|
|
int accum[2];
|
|
int battery_param_ver;
|
|
};
|
|
|
|
struct s2mf301_fuelgauge_platform_data {
|
|
int fuel_alert_soc;
|
|
int fuel_alert_vol;
|
|
|
|
unsigned int capacity_full;
|
|
|
|
char *fuelgauge_name;
|
|
|
|
struct sec_charging_current *charging_current;
|
|
};
|
|
|
|
struct s2mf301_fuelgauge_data {
|
|
struct device *dev;
|
|
struct i2c_client *i2c;
|
|
struct i2c_client *pmic;
|
|
struct mutex fuelgauge_mutex;
|
|
struct s2mf301_fuelgauge_platform_data *pdata;
|
|
struct power_supply *psy_fg;
|
|
/* struct delayed_work isr_work; */
|
|
|
|
int cable_type;
|
|
bool is_charging; /* charging is enabled */
|
|
int rsoc;
|
|
int mode;
|
|
u8 revision;
|
|
|
|
/* HW-dedicated fuelgauge info structure
|
|
* used in individual fuelgauge file only
|
|
* (ex. dummy_fuelgauge.c)
|
|
*/
|
|
struct fg_info info;
|
|
|
|
bool is_fuel_alerted;
|
|
struct wakeup_source *fuel_alert_ws;
|
|
|
|
unsigned int ui_soc;
|
|
unsigned int capacity_old;
|
|
|
|
bool initial_update_of_soc;
|
|
struct mutex fg_lock;
|
|
struct delayed_work isr_work;
|
|
|
|
/* register programming */
|
|
int reg_addr;
|
|
u8 reg_data[2];
|
|
u8 reg_OTP_53;
|
|
u8 reg_OTP_52;
|
|
|
|
int low_temp_limit;
|
|
int temperature;
|
|
|
|
int low_soc;
|
|
int low_vbat;
|
|
int high_temp;
|
|
int low_temp;
|
|
bool probe_done;
|
|
#if IS_ENABLED(TEMP_COMPEN) || IS_ENABLED(BATCAP_LEARN)
|
|
bool bat_charging; /* battery is charging */
|
|
#endif
|
|
#if IS_ENABLED(TEMP_COMPEN) && IS_ENABLED(BATCAP_LEARN)
|
|
int fcc;
|
|
int rmc;
|
|
#endif
|
|
#if IS_ENABLED(TEMP_COMPEN)
|
|
bool vm_status; /* Now voltage mode or not */
|
|
bool pre_vm_status;
|
|
bool pre_is_charging;
|
|
bool pre_bat_charging;
|
|
bool flag_mapping;
|
|
|
|
int socni;
|
|
int soc0i;
|
|
int comp_socr; /* 1% unit */
|
|
int pre_comp_socr; /* 1% unit */
|
|
int init_start;
|
|
int soc_r;
|
|
int avg_curr;
|
|
|
|
int i_socr_coeff;
|
|
int t_socr_coeff;
|
|
#endif
|
|
#if IS_ENABLED(BATCAP_LEARN)
|
|
bool learn_start;
|
|
bool cond1_ok;
|
|
int c1_count;
|
|
int c2_count;
|
|
int capcc;
|
|
int batcap_ocv;
|
|
int batcap_ocv_fin;
|
|
int cycle;
|
|
int soh;
|
|
#endif
|
|
};
|
|
|
|
#if IS_ENABLED(BATCAP_LEARN)
|
|
/* cycle, rLOW_EN, rC1_num, rC2_num, rC1_CURR, rWide_lrn_EN, Fast_lrn_EN, Auto_lrn_EN */
|
|
int BAT_L_CON[8] = {2, 0, 10, 10, 500, 0, 0, 1};
|
|
#endif
|
|
|
|
#endif /* __S2MF301_FUELGAUGE_H */
|