kernel_samsung_a53x/drivers/iio
Nuno Sa 7f83e105bd iio: adc: ad9467: fix scale setting
[ Upstream commit b73f08bb7fe5a0901646ca5ceaa1e7a2d5ee6293 ]

When reading in_voltage_scale we can get something like:

root@analog:/sys/bus/iio/devices/iio:device2# cat in_voltage_scale
0.038146

However, when reading the available options:

root@analog:/sys/bus/iio/devices/iio:device2# cat
in_voltage_scale_available
2000.000000 2100.000006 2200.000007 2300.000008 2400.000009 2500.000010

which does not make sense. Moreover, when trying to set a new scale we
get an error because there's no call to __ad9467_get_scale() to give us
values as given when reading in_voltage_scale. Fix it by computing the
available scales during probe and properly pass the list when
.read_available() is called.

While at it, change to use .read_available() from iio_info. Also note
that to properly fix this, adi-axi-adc.c has to be changed accordingly.

Fixes: ad6797120238 ("iio: adc: ad9467: add support AD9467 ADC")
Signed-off-by: Nuno Sa <nuno.sa@analog.com>
Reviewed-by: David Lechner <dlechner@baylibre.com>
Link: https://lore.kernel.org/r/20231207-iio-backend-prep-v2-4-a4a33bc4d70e@analog.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>
2024-11-18 12:12:49 +01:00
..
accel Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
adc iio: adc: ad9467: fix scale setting 2024-11-18 12:12:49 +01:00
addac Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
afe Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
amplifiers Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
buffer Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
chemical Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
common iio: common: ms_sensors: ms_sensors_i2c: fix humidity conversion time table 2024-11-18 12:12:00 +01:00
dac Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
dummy Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
frequency Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
gyro Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
health Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
humidity Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
imu iio: imu: inv_mpu6050: fix an error code problem in inv_mpu6050_read_raw 2024-11-18 12:12:00 +01:00
light Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
magnetometer Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
multiplexer Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
orientation Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
position Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
potentiometer Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
potentiostat Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
pressure iio: pressure: ms5611: ms5611_prom_is_valid false negative bug 2024-11-08 11:25:49 +01:00
proximity Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
resolver Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
temperature Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
trigger Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
iio_core.h Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
iio_core_trigger.h Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
industrialio-buffer.c Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
industrialio-configfs.c Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
industrialio-core.c Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
industrialio-event.c Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
industrialio-sw-device.c Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
industrialio-sw-trigger.c Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
industrialio-trigger.c Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
industrialio-triggered-event.c Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
inkern.c Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
Kconfig Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
Makefile Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00
TODO Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00