[ Upstream commit 3f9a91b6c00e655d27bd785dcda1742dbdc31bda ]
The Innolux G101ICE-L01 datasheet [1] page 17 table
6.1 INPUT SIGNAL TIMING SPECIFICATIONS
indicates that maximum vertical blanking time is 40 lines.
Currently the driver uses 29 lines.
Fix it, and since this panel is a DE panel, adjust the timings
to make them less hostile to controllers which cannot do 1 px
HSA/VSA, distribute the delays evenly between all three parts.
[1] https://www.data-modul.com/sites/default/files/products/G101ICE-L01-C2-specification-12042389.pdf
Fixes: 1e29b840af9f ("drm/panel: simple: Add Innolux G101ICE-L01 panel")
Signed-off-by: Marek Vasut <marex@denx.de>
Reviewed-by: Neil Armstrong <neil.armstrong@linaro.org>
Link: https://patchwork.freedesktop.org/patch/msgid/20231008223256.279196-1-marex@denx.de
Signed-off-by: Sasha Levin <sashal@kernel.org>
[ Upstream commit 06fc41b09cfbc02977acd9189473593a37d82d9b ]
Add missing .bus_flags = DRM_BUS_FLAG_DE_HIGH to this panel description,
ones which match both the datasheet and the panel display_timing flags .
Fixes: 1e29b840af9f ("drm/panel: simple: Add Innolux G101ICE-L01 panel")
Signed-off-by: Marek Vasut <marex@denx.de>
Reviewed-by: Neil Armstrong <neil.armstrong@linaro.org>
Link: https://patchwork.freedesktop.org/patch/msgid/20231008223315.279215-1-marex@denx.de
Signed-off-by: Sasha Levin <sashal@kernel.org>