commit b47c0fee73a810c4503c4a94ea34858a1d865bba upstream.
According to the BME68x Sensor API [1], the h6 calibration
data variable should be an unsigned integer of size 8.
[1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L789
Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor")
Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
Link: https://lore.kernel.org/r/20240606212313.207550-3-vassilisamir@gmail.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit ae1f7b93b52095be6776d0f34957b4f35dda44d9 upstream.
The IIO standard units are measured in kPa while the driver
is using hPa.
Apart from checking the userspace value itself, it is mentioned also
in the Bosch API [1] that the pressure value is in Pascal.
[1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L742
Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor")
Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
Link: https://lore.kernel.org/r/20240606212313.207550-2-vassilisamir@gmail.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>