Commit graph

3 commits

Author SHA1 Message Date
Vasileios Amoiridis
590019a0cd iio: chemical: bme680: Fix calibration data variable
commit b47c0fee73a810c4503c4a94ea34858a1d865bba upstream.

According to the BME68x Sensor API [1], the h6 calibration
data variable should be an unsigned integer of size 8.

[1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L789

Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor")
Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
Link: https://lore.kernel.org/r/20240606212313.207550-3-vassilisamir@gmail.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2024-11-19 14:19:33 +01:00
Vasileios Amoiridis
9a466d9b57 iio: chemical: bme680: Fix pressure value output
commit ae1f7b93b52095be6776d0f34957b4f35dda44d9 upstream.

The IIO standard units are measured in kPa while the driver
is using hPa.

Apart from checking the userspace value itself, it is mentioned also
in the Bosch API [1] that the pressure value is in Pascal.

[1]: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x_defs.h#L742

Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor")
Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
Link: https://lore.kernel.org/r/20240606212313.207550-2-vassilisamir@gmail.com
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
2024-11-19 14:19:33 +01:00
Gabriel2392
7ed7ee9edf Import A536BXXU9EXDC 2024-06-15 16:02:09 -03:00