pwm: imx-tpm: Use correct MODULO value for EPWM mode
commit cc6a931d1f3b412263d515fd93b21fc0ca5147fe upstream. The modulo register defines the period of the edge-aligned PWM mode (which is the only mode implemented). The reference manual states: "The EPWM period is determined by (MOD + 0001h) ..." So the value that is written to the MOD register must therefore be one less than the calculated period length. Return -EINVAL if the calculated length is already zero. A correct MODULO value is particularly relevant if the PWM has to output a high frequency due to a low period value. Fixes: 738a1cfec2ed ("pwm: Add i.MX TPM PWM driver support") Cc: stable@vger.kernel.org Signed-off-by: Erik Schumacher <erik.schumacher@iris-sensing.com> Link: https://lore.kernel.org/r/1a3890966d68b9f800d457cbf095746627495e18.camel@iris-sensing.com Signed-off-by: Uwe Kleine-König <ukleinek@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
5be6663698
commit
ae14643f35
1 changed files with 3 additions and 1 deletions
|
@ -106,7 +106,9 @@ static int pwm_imx_tpm_round_state(struct pwm_chip *chip,
|
|||
p->prescale = prescale;
|
||||
|
||||
period_count = (clock_unit + ((1 << prescale) >> 1)) >> prescale;
|
||||
p->mod = period_count;
|
||||
if (period_count == 0)
|
||||
return -EINVAL;
|
||||
p->mod = period_count - 1;
|
||||
|
||||
/* calculate real period HW can support */
|
||||
tmp = (u64)period_count << prescale;
|
||||
|
|
Loading…
Reference in a new issue