rtc: abx80x: Fix WDT bit position of the status register
[ Upstream commit 10e078b273ee7a2b8b4f05a64ac458f5e652d18d ] The WDT bit in the status register is 5, not 6. This fixes from 6 to 5. Link: https://abracon.com/Support/AppsManuals/Precisiontiming/AB08XX-Application-Manual.pdf Link: https://www.microcrystal.com/fileadmin/Media/Products/RTC/App.Manual/RV-1805-C3_App-Manual.pdf Fixes: 749e36d0a0d7 ("rtc: abx80x: add basic watchdog support") Cc: Jeremy Gebben <jgebben@sweptlaser.com> Signed-off-by: Nobuhiro Iwamatsu <iwamatsu@nigauri.org> Link: https://lore.kernel.org/r/20241008041737.1640633-1-iwamatsu@nigauri.org Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
parent
4bf42f2715
commit
189daa3156
1 changed files with 1 additions and 1 deletions
|
@ -37,7 +37,7 @@
|
|||
#define ABX8XX_REG_STATUS 0x0f
|
||||
#define ABX8XX_STATUS_AF BIT(2)
|
||||
#define ABX8XX_STATUS_BLF BIT(4)
|
||||
#define ABX8XX_STATUS_WDT BIT(6)
|
||||
#define ABX8XX_STATUS_WDT BIT(5)
|
||||
|
||||
#define ABX8XX_REG_CTRL1 0x10
|
||||
#define ABX8XX_CTRL_WRITE BIT(0)
|
||||
|
|